func TestParseGetStorageInfoOutputLulu(t *testing.T) {
const out = `$ hdparm -I /dev/sda
/dev/sda:
ATA device, with non-removable media
Model Number: SanDisk SSD U110 16GB
Serial Number: 145138402365
Firmware Revision: U221000
Transport: Serial, ATA8-AST, SATA Rev 2.6, SATA Rev 3.0
Standards:
Used: unknown (minor revision code 0x0110)
Supported: 9 8 7 6 5
Likely used: 9
Configuration:
Logical max current
cylinders 16383 16383
heads 16 16
sectors/track 63 63
--
CHS current addressable sectors: 16514064
LBA user addressable sectors: 31277232
LBA48 user addressable sectors: 31277232
Logical Sector size: 512 bytes
Physical Sector size: 512 bytes
Logical Sector-0 offset: 0 bytes
device size with M = 1024*1024: 15272 MBytes
device size with M = 1000*1000: 16013 MBytes (16 GB)
cache/buffer size = unknown
Form Factor: 1.8 inch
Nominal Media Rotation Rate: Solid State Device
Capabilities:
LBA, IORDY(can be disabled)
Queue depth: 32
Standby timer values: spec'd by Standard, no device specific minimum
R/W multiple sector transfer: Max = 1 Current = 1
Advanced power management level: disabled
DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 udma3 udma4 udma5 *udma6
Cycle time: min=120ns recommended=120ns
PIO: pio0 pio1 pio2 pio3 pio4
Cycle time: no flow control=120ns IORDY flow control=120ns
Commands/features:
Enabled Supported:
* SMART feature set
Security Mode feature set
* Power Management feature set
* Write cache
* Look-ahead
* Host Protected Area feature set
* WRITE_BUFFER command
* READ_BUFFER command
* NOP cmd
* DOWNLOAD_MICROCODE
Advanced Power Management feature set
SET_MAX security extension
* 48-bit Address feature set
* Device Configuration Overlay feature set
* Mandatory FLUSH_CACHE
* FLUSH_CACHE_EXT
* SMART error logging
* SMART self-test
* General Purpose Logging feature set
* 64-bit World wide name
* WRITE_UNCORRECTABLE_EXT command
* Segmented DOWNLOAD_MICROCODE
* Gen1 signaling speed (1.5Gb/s)
* Gen2 signaling speed (3.0Gb/s)
* Gen3 signaling speed (6.0Gb/s)
* Native Command Queueing (NCQ)
* Phy event counters
* Device-initiated interface power management
* Software settings preservation
Device Sleep (DEVSLP)
* SANITIZE feature set
* BLOCK_ERASE_EXT command
* SET MAX SETPASSWORD/UNLOCK DMA commands
* DEVICE CONFIGURATION SET/IDENTIFY DMA commands
* Data Set Management TRIM supported (limit 8 blocks)
* Deterministic read data after TRIM
Security:
Master password revision code = 65534
supported
not enabled
not locked
not frozen
not expired: security count
supported: enhanced erase
2min for SECURITY ERASE UNIT. 2min for ENHANCED SECURITY ERASE UNIT.
Logical Unit WWN Device Identifier: 5001b44cd681403d
NAA : 5
IEEE OUI : 001b44
Unique ID : cd681403d
Checksum: correct
$ smartctl -x /dev/sda
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-3.14.0] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SanDisk based SSDs
Device Model: SanDisk SSD U110 16GB
Serial Number: 145138402365
LU WWN Device Id: 5 001b44 cd681403d
Firmware Version: U221000
User Capacity: 16,013,942,784 bytes [16.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 1.8 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Jul 30 21:28:57 2019 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 3) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O---- 100 100 000 - 0
9 Power_On_Hours -O---- 100 100 000 - 333
12 Power_Cycle_Count -O---- 100 100 000 - 1758
165 Total_Write/Erase_Count -O---- 100 100 000 - 174113
171 Program_Fail_Count -O---- 100 100 000 - 0
172 Erase_Fail_Count -O---- 100 100 000 - 0
173 Avg_Write/Erase_Count -O---- 100 100 000 - 86
174 Unexpect_Power_Loss_Ct -O---- 100 100 000 - 17
187 Reported_Uncorrect -O---- 100 100 000 - 0
194 Temperature_Celsius -O---K 055 045 000 - 45 (Min/Max 14/57)
230 Perc_Write/Erase_Count -O---- 100 100 000 - 286
232 Perc_Avail_Resrvd_Space PO---- 100 100 005 - 0
234 Perc_Write/Erase_Ct_BC -O---- 100 100 000 - 252
241 Total_LBAs_Written -O---- 100 100 000 - 2117789970
242 Total_LBAs_Read -O---- 100 100 000 - 1714398091
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x03 GPL,SL R/O 16 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 GPL,SL R/O 1 SMART self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 1 Device vendor specific log
0xa2 GPL,SL VS 2 Device vendor specific log
0xa3 GPL,SL VS 1 Device vendor specific log
0xa6-0xa7 GPL,SL VS 255 Device vendor specific log
Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
SMART Extended Comprehensive Error Log Version: 1 (16 sectors)
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 45 --- Current Temperature
0x05 0x010 1 - --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 57 --- Highest Temperature
0x05 0x028 1 26 --- Lowest Temperature
0x05 0x030 1 - --- Highest Average Short Term Temperature
0x05 0x038 1 - --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 95 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 2 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 461 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0001 2 0 Command failed due to ICRC error
`
info, err := parseGetStorageInfoOutput(context.Background(), []byte(out))
if err != nil {
t.Fatal("parseGetStorageInfoOutput() failed: ", err)
}
exp := &Info{
Name: "145138402365",
Device: SSD,
Status: Healthy,
PercentageUsed: 2,
TotalBytesWritten: 1084308464640,
}
if !reflect.DeepEqual(info, exp) {
t.Errorf("parseGetStorageInfoOutput() = %+v; want %+v", info, exp)
}
}